Single box amplified Titanium::Sapphire femtosecond laser system
University of Jyväskylä · Keski-Suomi
Perustiedot
- Tarjousten määräaika
- su 31.1.2021 klo 23.59 (päättynyt)
- Hankkija
- University of Jyväskylä, Y-tunnus 0245894-7
- Toteutuspaikka
- Keski-Suomi (FI198)
- University of Jyväskylä, Nanoscience Center / Department of Chemistry
- Hankintalaji
- Tavarahankinta
- Menettely
- EU-hankinta
- Ilmoituksen tyyppi
- Hankintailmoitus
- Arvioitu kokonaisarvo
- 240 000 € (alv 0 %)
- Pääasiallinen CPV
- 38636100 Laserit
- Julkaistu
- 14.1.2021
- Korjausilmoitus
Ilmoituksen teksti
Alkuperäinen teksti Hilmasta, muuttamattomanaSingle box amplified Titanium::Sapphire femtosecond laser system for pumping several independent measurement stations at minimally 1 kHz repetition rate. Laser output will be splitted to four independent measurement stations in energy ratios 1.2 mJ, 1.2 mJ, 1.2 mJ and remaining power (>1.2mJ). Measurement stations will use fundamental laser radiation for pumping OPAs and NOPAs, and for a second/third harmonic generation and white light generation.
It is expected that needed splitting optics will be delivered with the laser system. Pulse duration can be between 80-100 fs, while shorter is considered to be better due to overall time resolution for the experiments using laser fundamental/OPA radiation.
Contracting authority (JYU) may suspend the procurement procedure if the tenders exceed the budget available for the procurement.
Prior references of supplying comparable systems are required.
Erän kuvaus
Single box amplified Titanium::Sapphire femtosecond laser system for pumping several independent measurement stations at minimally 1 kHz repetition rate. Laser output will be splitted to four independent measurement stations in energy ratios 1.2 mJ, 1.2 mJ, 1.2 mJ and remaining power (>1.2mJ). Measurement stations will use fundamental laser radiation for pumping OPAs and NOPAs, and for a second/third harmonic generation and white light generation.
It is expected that needed splitting optics will be delivered with the laser system. Pulse duration can be between 80-100 fs, while shorter is considered to be better due to overall time resolution for the experiments using laser fundamental/OPA radiation.
Contracting authority (JYU) may suspend the procurement procedure if the tenders exceed the budget available for the procurement.
Prior references of supplying comparable systems are required.
Muutoksen kuvaus
Added time limits for requirements:
- Pulse energy stability: <0.5 % RMS for fundamental and <1
% RMS for SHG (24 hours)
- Stability: SHG <0.8 % RMS (8 hours) = 5 points